Upgrading Panatrack GP

Upgrading Panatrack GP

Upgrading Panatrack GP

This guide walks you through a full Panatrack GP upgrade: backing up, running the installer, verifying the portal, updating the handhelds, confirming a few settings afterward, and running upgrade scripts only when they are needed. Work through the steps in order.

IMPORTANT: Do not skip the backup in Step 1. Keep the backups available in case recovery is needed.

What You Need

  • The Panatrack GP installer for the version you are upgrading to.
  • Administrator access to the server that hosts Panatrack GP.
  • Access to the SQL Server that hosts your Dynamics GP databases, so you can back up the Panatrack GP database and, if needed, back up affected GP company databases and run the scripts identified by Panatrack Support.
  • An administrator login to the Panatrack GP portal.
  • The handhelds that run Panatrack GP, gathered so you can update them together.

Before You Begin

  • Schedule downtime for the upgrade. Have users finish their transactions and exit Panatrack GP before you take the backups. Keep users out until the upgrade and verification steps are complete.
  • In the portal, go to Administration → System Status and record the current Panatracker Version, Database host, Database name, and System Adapter. Keep these details available during installation.
  • Before starting, confirm with Panatrack Support whether scripts are needed for your current and target versions. If they are, confirm which scripts to run, which databases they affect, and when and in what order to run them. Follow that sequence for the script steps.

Step 1: Back Up the Database and Site Files

Before you install anything, back up the database and site files. If scripts are required, also back up the GP company databases they affect.

  1. Back up the Panatrack GP database on the SQL Server that hosts your GP databases. If Support has identified scripts that affect GP company databases, back up each affected company database before running those scripts.
  2. On the server hosting Panatrack GP, locate the site files. By default they are at C:\Program Files (x86)\Panatrack\PanatrackerGP_V7.
  3. Create a new, dated backup folder, such as Portal-backup-YYYY-MM-DD, one directory up in C:\Program Files (x86)\Panatrack. Copy the Portal folder into that backup folder. Use a unique folder name for each upgrade so you do not overwrite or merge with an older backup.

Keep the database backups and Portal folder copy together. If the upgrade fails, contact Panatrack Support for recovery guidance before restoring either the database backups or the Portal folder.

Step 2: Run the Installer

  1. Run the Panatrack GP installer as an administrator.
  2. Click Next on the first screen.
  3. Accept the license agreement and click Next.
  4. Confirm the install directory. By default it is C:\Program Files (x86)\Panatrack\PanatrackerGP_V7, the same folder you backed up in Step 1.
  5. Check the connection string. It is pulled in from your current installation and should already be correct, but confirm it against the portal's System Status page: Data Source should match Database host, and Initial Catalog should match Database name. If both match, click Next.
  6. Choose the version of Dynamics GP that Panatrack GP integrates with. You can confirm this on the System Status page under System Adapter. Click Next.
  7. Confirm your SMTP settings. These carry over from your previous setup and should already be correct.
  8. Click Install.

Step 3: Refresh the Portal and Run Diagnostics

  1. Refresh or navigate to the Panatrack GP portal. It takes a minute to come up while the upgrade finishes.
  2. Once it loads, go to Administration → System Status and confirm the Panatracker Version matches the installer you just ran.
  3. Go to Administration → Diagnostics and select the Host Test tab.
  4. Run Perform Test on each company in the dropdown to confirm the eConnect integration is working. Every profile should return Success.

Step 4: Upgrade the Handhelds

  1. Gather the handhelds running Panatrack GP.
  2. Close the Panatrack GP app on each device and reopen it.
  3. Each device prompts for a required update. Accept it.
  4. The upgrade runs on its own. The database upgrade step can take a while, so do not worry if it looks stalled there.
  5. Once a handheld reaches the login screen or main menu, check the Device Setup page in the portal to confirm it shows the upgraded version.

Step 5: Confirm Your Settings After the Upgrade

NOTE: This check only matters if you use Windows Mobile handhelds. The Android app does not use these settings. If your system was running version 7.4.6 or later before this upgrade and any of these were set to False, they stay False after upgrading, and the updated handheld screens will not work until they are set to True.

A few settings need to be checked once the upgrade is done.

  1. In the portal, go to Configure → System Settings → Feature & Transaction Access Settings → Transaction Compatibility. Confirm these are set to True:
    • Enable New Add Inventory
    • Enable New Remove Inventory
    • Enable New Site Transfer
    • Enable New Item Bin Move
    • Enable New Put Away
  2. If you use Panatrack GP for manufacturing transactions, also confirm these are set to True in the same section:
    • Enable New Issue Inventory
    • Enable New Create Production (beta)

Step 6: Run Upgrade Scripts (Only If Needed)

IMPORTANT: Only run scripts if Panatrack Support has confirmed they are required for your upgrade. Follow the timing and sequence confirmed before you began; some scripts may need to run earlier in the process. If no scripts are required, skip this step.

Go to Administration → System Status in the portal, then edit the URL to replace SystemStatus at the end with Scripts, for example http://pgp_server_name:81/Admin/Scripts. Run only the scripts Panatrack Support identifies for your upgrade, against the databases and in the order Support specifies. Confirm that you have backups of the affected databases before running any scripts.


If Something Doesn't Work

Contact Panatrack Support at support@panatrack.com or visit support.panatrack.com. Include the Panatracker Version shown on the System Status page and, if a Host Test failed, the message it returned.